
- #Sax video 2011 software manual
- #Sax video 2011 software upgrade
- #Sax video 2011 software software
- #Sax video 2011 software password
Fixed problem with Guinier plots not being loaded from AAP results (issue #9444). Fixed problem with curve generation when adjusting distance based on sample Z position and calibration does not contain valid Z stage offset information (issue #9466). Fixed problem with calibration refinement results not propagating correctly (issue #9461). Fixed problem with automatic Kratky block (3-axis) alignment for targets greater than 30 (issue #9421). Fixed problem with automatic Kratky block (2-axis) alignment for targets greater than 30 (issue #9421). #Sax video 2011 software manual
Changed move button in manual Kratky block alignment to move block to position shown in plot (issue #9451). Changed manual 3D Kratky block alignment to use 3 decimal places for angles (issue #9365). Added zoom in/out to sample and auto alignment plots (issue #9419). Added warning when reading calibration file that does not contain valid Z stage offset information when adjusting distance based on sample Z position (issue #9466). Added soak time indication to status display (issue #9443). Added selection of region used for peak position calculation in sample alignment plot (issue #9420). Added selecting of data points on plots in Processing task (issue #9385). Added lock button for moving Z axis in manual control (issue #9457). Added button to sample position tool for moving to the open beam position (issue #9441). #Sax video 2011 software password
Added administrative password to editing or adding Q/Flux position definitions (issue #9454). Added use of secure connection when downloading help videos, with fall-back to non-secure connection. Added task for for scaling SAXS and WAXS curves together. Added support for variable temperature stages. Added support for saving load/unload and calibration positions for multiple sample stages (issue #9435).
Added support for reading/writing curves in canSAS1D format.Added support for generating curves using absolute intensity correction (issue #9425).Added support for converting images to TIFF format.Added support back in for AAP version 2.5, which was dropped in version 3.2.0.Added summing and averaging of 1D curves with different q ranges (issue #9429).Added option for displaying error bars on 1D curves.Added main menu items for exporting alignment plot data as a text file (issue #9460).Added LaB₆ (lanthanum hexaboride) as a calibration standard (issue #9397).The following is a list of changes and improvements that have been implemented in SAXSLab 4.1.0
#Sax video 2011 software upgrade
If you have an existing SAXSLab license but are out of warranty and not on a service contract, you can purchase an upgrade via the request the download information form.
#Sax video 2011 software software
If you have all of the information listed above, you can download the software from the Web site. Once we receive your request, we will send the information via e-mail to the contact person listed in the request.
If you have not received the username and password information, you can request the download information. The name and e-mail address of your organization's contact person.The username and password sent (via e-mail) to your organization's contact person.Before you download the software, you will need the following information: